A Sauer-Danfoss (Sundstrand) Series 90 pump model code reads left to right in fixed fields: 90 for the series, R or L for rotation, three digits for the frame size in cc per revolution, then the control, pressure regulation, auxiliary pad, end cap ports, filtration, displacement limiters, shaft, charge pump, control orifices, special hardware, the two high-pressure settings and the charge pressure setting. So 90R100 is a Series 90 pump, right-hand (clockwise) rotation, 100 cc maximum displacement.
Everything after that tells you how the pump was built, and several fields change which parts fit. This page decodes every field from the Danfoss Series 90 technical information (520L0603), works through a real nameplate code, and explains the serial number and date code, which matter for ordering parts as much as the model code does.
The example code Danfoss prints in its Series 90 100 cc parts manual (520L0893)
| Field | Example | Meaning | Matters for parts? |
|---|---|---|---|
| Series | 90 |
Series 90 axial piston pump | Yes |
| R | L |
Type and rotation, R right hand (CW), L left hand (CCW) | Yes, charge pump and some internals |
| Size | 100 |
Maximum displacement, cc per revolution | Yes, sets almost every part |
| M | EP |
Displacement control | Yes, control and control seal kit |
| P | 1 |
High-pressure regulation | Yes, multi-function valves |
| J | CD |
Auxiliary mounting pad | Yes |
| G | 60 |
End cap ports | Yes, end cap and gasket |
| N | P |
Filtration | Yes |
| F | 3 |
Displacement limitation | Sometimes |
| L | F1 |
Input shaft | Yes |
| H | D |
Charging system (charge pump size) | Yes |
| T | 03 |
Control orifices | Yes, when rebuilding the control |
| W | GBA |
Special hardware, mostly valve plate and sensor | Yes, valve plate |
| Y | 35 |
High-pressure setting, port A, in tens of bar | Yes, valve cartridge setting |
| Z | 35 |
High-pressure setting, port B, in tens of bar | Yes, valve cartridge setting |
| K | 24 |
Charge pressure setting, bar | Yes, charge relief |
Send the whole code, plus the date code. The model code defines the build, but Danfoss parts lists often give two or more part numbers for the same item, split by date of manufacture. Without the date code we may have to guess, and we would rather not. More on that below.
What does 90R100 mean? Frame sizes and displacement
The three digits after the rotation letter are the frame size, which is the maximum displacement in cc per revolution. Danfoss builds seven pump frames.
| Code | Max displacement | Rated speed | Max speed | Base unit weight |
|---|---|---|---|---|
042 |
42 cc (2.56 in³) | 4200 rpm | 4600 rpm | 34 kg (75 lb) |
055 |
55 cc (3.35 in³) | 3900 rpm | 4250 rpm | 40 kg (88 lb) |
075 |
75 cc (4.57 in³) | 3600 rpm | 3950 rpm | 49 kg (108 lb) |
100 |
100 cc (6.10 in³) | 3300 rpm | 3650 rpm | 68 kg (150 lb) |
130 |
130 cc (7.93 in³) | 3100 rpm | 3400 rpm | 88 kg (195 lb) |
180 |
180 cc (10.98 in³) | 2600 rpm | 2850 rpm | 136 kg (300 lb) |
250 |
250 cc (15.25 in³) | 2300 rpm | 2500 rpm | 154 kg (340 lb) |
Rated system pressure for the family is 420 bar (6000 psi), maximum 480 bar (7000 psi), per the Series 90 service manual 520L0818. Figures are from that manual's operating parameters table.
The letter after 90 on a pump is R or L. You will also see 90M on Series 90 fixed motors, which use their own code and are not decoded here.
Control codes (field M)
The two letters after the frame size tell you how the pump is stroked. This is the field that most often decides the control, the control gasket and the seal kit for the control.
| Code | Control |
|---|---|
CA |
Cover plate, no feedback link, no control |
DC |
3-position F-N-R solenoid control, 12 V DC, DIN connector |
DD |
3-position F-N-R solenoid control, 24 V DC, DIN connector |
HF |
HDC 2 hydraulic displacement control, standard porting, 3.0-11 bar (44-160 psi) signal |
KA |
EDC electric displacement control, MS connector, dual coil (14-85 mA) |
KN |
EDC, MS connector, 643 ohm single coil (4-20 mA) |
KT |
EDC, Deutsch connector, dual coil (14-85 mA) |
KP |
EDC, Weatherpack connector, dual coil (14-85 mA) |
MA |
MDC manual displacement control |
MB |
MDC with neutral start switch |
FA / FB
|
NFPE electrohydraulic control, no feedback link, 12 V / 24 V, AMP Minitimer connector, 25 bar pressure reducing valve |
FC / FD
|
NFPE, 12 V / 24 V, 32 bar pressure reducing valve |
FG / FH
|
NFPE, 12 V / 24 V, 32 bar, fast response |
FK / FL
|
NFPE, 12 V / 24 V, 25 bar (075 frame only) |
FM / FN
|
NFPE, 12 V / 24 V, 32 bar, fast response (075 frame only) |
Older plates carry control codes that are not in the current list. The example code above uses EP, which the 100 cc parts manual identifies as an EDC with a Packard connector. The same manual lists EA and EH as EDC with an MS connector and EK as EDC with a Deutsch connector. If your code is not in the table, it is not a misprint. Send it to us and we will look it up against the parts manual for your frame.
High-pressure regulation (field P)
| Code | Meaning |
|---|---|
1 |
Pressure limiter for ports A and B, 140-450 bar |
2 |
High-pressure relief valves for ports A and B, 90-450 bar |
Auxiliary mounting pad (field J)
| Code | Pad | Frames |
|---|---|---|
AB |
SAE-A, sealed cover, 9-tooth coupling | All |
BB |
SAE-BB, sealed cover, 15-tooth coupling | All |
BC |
SAE-B, sealed cover, 13-tooth coupling | All |
CD |
SAE-C, sealed cover, 4-bolt adapter, 14-tooth coupling | 055 through 250 |
DE |
SAE-D, sealed cover, 13-tooth coupling | 130, 180, 250 |
EF |
SAE-E, sealed cover, 13-tooth coupling | 180, 250 |
NN |
No auxiliary mounting pad | All |
End cap ports (field G) and filtration (field N)
| Code | End cap | Frames |
|---|---|---|
60 |
Side ports | 055, 075, 100 |
80 |
Twin ports | All |
| Code | Filtration | Frames |
|---|---|---|
D |
External charge pump | All |
L |
Pressure filter, integral, long filter | 042 through 130 |
P |
Pressure filter, integral, short filter | 042 through 130 |
R |
Remote pressure filtration | 055 through 130 |
T |
Remote pressure, SAE 1-1/16 thread ports for high flow | 180, 250 |
S |
Suction filtration | All |
Displacement limitation (field F)
| Code | Meaning |
|---|---|
3 |
No limiters (not offered on 180) |
4 |
Limiters on both sides (not offered on 180) |
C |
No limiters, 180 cc only |
M |
Limiters on both sides, 180 cc only |
7 |
No limiters, special servo cylinder on side 1 with hard spring, NFPE controls only |
Input shaft (field L)
| Code | Shaft | Frames |
|---|---|---|
C3 |
Splined, 15 teeth, 16/32 pitch | 042 |
C6 |
Splined, 21 teeth, 16/32 pitch | 055, 075, 100 |
C7 |
Splined, 23 teeth, 16/32 pitch | 075, 100 |
C8 |
Splined, 27 teeth, 16/32 pitch | 130, 180, 250 |
F1 |
Splined, 13 teeth, 8/16 pitch | 100, 130, 180, 250 |
S1 |
Splined, 14 teeth, 12/24 pitch | 055, 075, 100 |
G1 |
Splined, 25 teeth, 20/40 pitch | 075, 100 |
T8 |
Tapered, 25.400 mm (1.000 in) diameter | 042 |
T1 |
Tapered, 34.925 mm (1.375 in) diameter | 055, 075 |
T6 |
Tapered, 38.100 mm (1.500 in) diameter | 075, 100 |
T4 |
Tapered, 44.450 mm (1.750 in) diameter | 130 |
Charging system (field H)
This letter is the size of the charge pump on the back of the pump, or a note that charge comes from outside.
| Code | Charge pump | Frames |
|---|---|---|
B |
11 cc/rev | 042, 055 |
C |
14 cc/rev | 042, 055, 075 |
D |
17 cc/rev | 055, 075, 100 |
E |
20 cc/rev | 075, 100 |
F |
26 cc/rev | 100, 130 |
H |
34 cc/rev | 130, 180 |
J |
47 cc/rev | 180, 250 |
K |
65 cc/rev | 250 |
L |
External charge pump, internal charge relief, unit has an auxiliary pad | All |
N |
External charge pump, internal charge relief, unit has no auxiliary pad | All except 055 |
Control orifices (field T)
Two characters that set the orifices in the control. They change how fast the pump strokes, and the code only makes sense together with the control type in field M. Sizes are in millimeters.
| Control | Code | Inlet P | Drains | Servo A / B |
|---|---|---|---|---|
| MDC | 00 |
None | 1.6 (hole in spool, no orifice fitted) | None |
03 |
0.81 | 1.6 (hole in spool) | None | |
05 |
1.37 | 1.6 (hole in spool) | None | |
C5 |
0.81 | 1.4 | None | |
C6 |
1.02 | 1.4 | None | |
| EDC | 00 |
None | 1.3 | None |
03 |
0.81 | 1.3 | None | |
05 |
1.37 | 1.3 | None | |
33 |
0.81 | None | None | |
| FNR | G1 |
None | 1.2 | None |
G4 |
0.46 | 1.2 | None | |
G8 |
0.66 | 1.2 | None | |
GB |
0.81 | 1.2 | None | |
GD |
1.57 | 1.2 | None | |
| HDC | 00 |
None | 1.3 | None |
03 |
0.81 | 1.3 | None | |
05 |
1.37 | 1.3 | None | |
| NFPE | B1 |
None | 1.5 | None |
B2 |
None | None | 1.2 / 1.2 | |
B6 |
None | None | None |
Special hardware (field W)
Three letters, mostly describing the valve plate, which is a rotating group part, so this field matters when you rebuild.
| Code | Meaning |
|---|---|
EEG |
Speed ring, no sensor, CP30 +4.3° valve plate |
EFC |
Speed sensing, Turck connector (KPPx156), CP15 +0.5° valve plate |
EFI |
Speed sensing, Turck connector (KPPx156), CP30 +4.3° valve plate |
FAC |
Nested T-bar springs, CP15 +1.5° valve plate |
FAD |
Nested T-bar springs, CP15 +0.5° valve plate |
GBA |
CP15 +0.5° valve plate |
GCA |
CP15 +1.5° valve plate |
GLA |
CP30 +4.3° valve plate |
NNN |
180 cc: CP15 +0.5° valve plate. 250 cc: CP15 +1.5° valve plate, nested T-bar springs |
High-pressure settings (fields Y and Z) and charge pressure (field K)
The last three groups are settings, not hardware, and they are the ones a mechanic reads most often.
| Field | Codes | Meaning |
|---|---|---|
| Y, port A |
26 32 35 38 40 42
|
260, 320, 350, 380, 400 or 420 bar |
| Z, port B |
26 32 35 38 40 42
|
260, 320, 350, 380, 400 or 420 bar |
| K, charge |
20 through 34 in steps of 2 |
Charge relief setting in bar. 32 is not offered on the 250, and 34 is not offered on the 042 or the 250. |
The service manual explains how to read them in the field. The high-pressure setting is the factory preset of the pressure limiter in each multi-function valve, and it is referenced to charge pressure, so it is the difference between the high and low sides of the loop. The charge setting is referenced to case pressure. Danfoss's measured ranges at 1500 rpm in neutral are 18.1-21.7 bar (262-315 psi) for code 20, 22.0-26.9 bar (319-390 psi) for code 24 and 25.8-30.7 bar (374-445 psi) for code 28. If your drive has a problem, our hydrostatic troubleshooting guide walks through those checks.
Worked example: 90L100 EP 1 CD 60 P 3 F1 D 03 GBA 35 35 24
This is the nameplate code Danfoss uses as its example in the Series 90 100 cc pump parts manual (520L0893). Decoded against the tables above:
| Field | Code | This pump |
|---|---|---|
| Series | 90 |
Series 90 pump |
| Rotation | L |
Left hand, counterclockwise |
| Size | 100 |
100 cc (6.10 in³) per revolution |
| Control | EP |
EDC electric displacement control, Packard connector (not in the 2016 master list, but listed in the parts manual) |
| Pressure regulation | 1 |
Pressure limiters on ports A and B |
| Auxiliary pad | CD |
SAE-C pad, 4-bolt adapter, 14-tooth coupling |
| End cap | 60 |
Side ports |
| Filtration | P |
Integral pressure filter, short |
| Displacement limiters | 3 |
None |
| Shaft | F1 |
13-tooth 8/16 pitch spline |
| Charge pump | D |
17 cc/rev |
| Control orifices | 03 |
EDC: 0.81 mm inlet, 1.3 mm drains |
| Special hardware | GBA |
CP15 +0.5° valve plate |
| High pressure A / B |
35 35
|
350 bar both sides |
| Charge pressure | 24 |
24 bar setting, measured 22.0-26.9 bar (319-390 psi) at 1500 rpm in neutral |
Danfoss uses the same code to show how a part is found: the shaft field reads F1, so you go to the shaft group in the parts list, find order code F1, and that gives the item and part number for the drive shaft. Every module on a Series 90 parts list is keyed to a field of the model code in exactly this way, which is why the full code saves so much back and forth. (The manual's step text calls the shaft code "S1" in one place, but the code itself and the next step both read F1.)
Serial number and date code: why they matter for parts
The nameplate carries three identifiers, and they do different jobs.
| Nameplate field | What it is | Example |
|---|---|---|
| Model code | Defines the unit completely. Danfoss says to use it when ordering service parts. | 90L100 EP 1 CD 60 P 3 F1 D 03 GBA 35 35 24 |
| Model number (Ident number) | The factory's manufacturing number. A complete repeat unit can be ordered by it. | 9621161 |
| Serial number | Plant letter, two-digit year, two-digit week, then a five-digit sequence number | A-01-26-23456 |
The letter at the start of the serial number is the place of assembly. The name plates in the Sauer-Sundstrand Series 90 service manual (BLN-9947, copyright 1987-1998) show A on a plate marked Ames, Iowa, U.S.A., and N on a plate marked Neumünster, Germany. The year and week that follow are the build date.
That date is the date code, and it is the part people skip. Danfoss parts lists frequently show the same item number with different part numbers for different build dates. The 100 cc parts manual's own example is the end cap gasket, item G30: units with a date code before 89-17 take part number 8000151, and units from 89-17 on take 8000243. Same pump, same model code, different gasket. Our Sundstrand and Sauer-Danfoss identification guide shows the same pattern in the Series 18 parts list, and it is the single biggest reason a wrong Sundstrand part gets shipped.
Photograph the whole plate. A model code typed from memory loses the date code and usually a field or two. A clear picture of the plate gets the right part first time.
Older Sundstrand and Sauer-Sundstrand Series 90 numbering
Series 90 literature has been published under Sauer-Sundstrand, Sauer-Danfoss and Danfoss names, and a unit's plate carries whichever name applied when it was built. The field order of the model code carried through, but older plates look different in a few ways:
-
Single-character fields. The sample pump plate in BLN-9947 reads
90L055 EA 1 N 6 S 3 C6 C 03 HNN 35 35 24. The auxiliary pad and end cap print as one character each (Nand6) where current codes print two (CDand60in our example). Read it field by field in the same order and it lines up. -
Retired codes.
EAandHNNon that plate do not appear in the 2016 master code. The parts manuals still list many retired codes, so an old code is not a sign of a fake or a misread plate. -
Different model number formats. The same BLN-9947 plates show a U.S. model number written as
94-2029and a German Ident number as six digits (687459). Newer Danfoss literature shows plain six- or seven-digit model numbers (501829on the sample plate in the 2016 technical information,9621161in the 100 cc parts manual), so read whatever format is on your plate and send it as printed.
If you have an older plate that does not fit any of this, send us a photo. We would rather look at it than have you guess.
Series 90 parts and seal kits
- Series 90 pump parts
- 55 cc seal kit 80020S30
- 75 cc seal kit 81020S30
- 100 cc seal kit 11035669
- Sundstrand seal kits
- Seal kit collection
- Sundstrand parts catalog
- Sundstrand piston pumps
Frequently asked questions
How do I read a Sauer-Danfoss Series 90 model code?
Read it left to right in fixed fields: 90 for the series, R or L for rotation, three digits for frame size in cc, then control, pressure regulation, auxiliary pad, end cap ports, filtration, displacement limiters, shaft, charge pump, control orifices, special hardware, high-pressure settings for ports A and B, and the charge pressure setting.
What does 90R100 mean?
A Series 90 pump with right-hand (clockwise) rotation and 100 cc (6.10 cubic inches) maximum displacement per revolution. Danfoss rates the 100 frame at 3300 rpm, with a 3650 rpm maximum.
What do the last numbers on a Series 90 model code mean?
The last three groups are settings. The first two are the high-pressure settings for ports A and B in tens of bar, so 35 is 350 bar. The final two digits are the charge pressure setting in bar, from 20 to 34.
What frame sizes does the Series 90 pump come in?
Seven: 042, 055, 075, 100, 130, 180 and 250, which are the maximum displacements in cc per revolution, from 2.56 to 15.25 cubic inches.
Where is the date code on a Series 90 pump?
In the serial number on the nameplate. After the plant letter come a two-digit year and a two-digit week of manufacture, then a sequence number. Parts lists use that year and week to pick between part numbers for the same item.
What do EDC, MDC, HDC, FNR and NFPE mean on a Series 90?
They are control types. EDC is electric displacement control, MDC is manual displacement control, HDC is hydraulic displacement control, FNR is a 3-position forward-neutral-reverse solenoid control, and NFPE is an electrohydraulic control without a feedback link.
About the technical information on this page. Figures, procedures and part numbers here come from manufacturer service literature and are provided for reference only. They are only as accurate as the factory data, and the revision we have on file may not be the latest for your unit. Always confirm against the current manufacturer documentation for your exact model and follow safe work practices. RestoPower is not responsible for damage, injury or loss resulting from the use or misuse of this information, or from incorrect assembly, adjustment, installation or operation of any unit.
Send the full code and the date code
Give us every field from the nameplate, the serial number, and what the machine is. With the code and the date we can match seal kits, shafts and control parts to your build. We reply with price, availability and lead time.
Request a quote · (810) 882-1171 · Repair and rebuild service
Related reading
- How to identify a Sundstrand or Sauer-Danfoss pump
- Hydrostatic transmission troubleshooting
- Sundstrand Series 20 and 90 guide
- Sundstrand brand hub
- Sundstrand document reference index
- Denison pump model code decoder
- How to Identify a Hydraulic Pump or Motor With No Tag
- Hydraulic Pump Case Drain Flow Test: How Much Is Too Much?